We are a leading Manufacturer of stainless steel boyles machine for operation use, boyles anesthesia machine, medical engineer anesthesia machines, anaesthesia machine boyles, mild steel boyles apparatus anesthesia machine and medical anesthesia machine from New Delhi, India.

Stainless Steel Boyles Machine For Operation Use

  • Stainless Steel Boyles Machine For Operation Use
  • Stainless Steel Boyles Machine For Operation Use
  • Stainless Steel Boyles Machine For Operation Use
Stainless Steel Boyles Machine For Operation Use
Get Best Quote
Rs 1,50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Automation GradeFully Automatic
TypeSimple Boyle's Apparatus
Model Name/NumberME-282
Usage/ApplicationOperation Use
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%, During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Boyles Anesthesia Machine

  • Boyles Anesthesia Machine
  • Boyles Anesthesia Machine
  • Boyles Anesthesia Machine
Boyles Anesthesia Machine
Get Best Quote
Rs 1,50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Automation GradeSemi Automatic
MaterialStainless Steel
TypePortable Boyle's Apparatus
Model Name/NumberME-282
Usage/ApplicationOperation Use
Country of OriginMade in India
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%
  • During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Medical Engineer Anesthesia Machines

  • Medical Engineer Anesthesia Machines
  • Medical Engineer Anesthesia Machines
  • Medical Engineer Anesthesia Machines
Medical Engineer Anesthesia Machines
Get Best Quote
Rs 1,50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

MaterialStainless Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-282
PositioningTrolley
FeaturesORC

Safety Features:

  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%, During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.


Additional Information:

  • Packaging Details: BOX

View Complete details

Yes! I am Interested Request a call back

Anaesthesia Machine BOYLES

  • Anaesthesia Machine BOYLES
  • Anaesthesia Machine BOYLES
  • Anaesthesia Machine BOYLES
Anaesthesia Machine BOYLES
Get Best Quote
Rs 1,50,000  / PiecePrice on Request
MaterialStainless Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-282
PositioningTrolley
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%
  • During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Mild Steel Boyles Apparatus Anesthesia Machine

  • Mild Steel Boyles Apparatus Anesthesia Machine
  • Mild Steel Boyles Apparatus Anesthesia Machine
  • Mild Steel Boyles Apparatus Anesthesia Machine
Mild Steel Boyles Apparatus Anesthesia Machine
Get Best Quote
Rs 1,50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Machine TypeBasic Boyles
No of Gas Lines2 gas
Vaporizer SlotsSingle
Automation GradeSemi Automatic
Usage/ApplicationOperation Use
TypeSimple Boyle's Apparatus
Model Name/NumberME-282
PositioningTrolley
MaterialMild Steel
Country of OriginMade in India
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%, During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Medical Anesthesia Machine

  • Medical Anesthesia Machine
  • Medical Anesthesia Machine
  • Medical Anesthesia Machine
Medical Anesthesia Machine
Get Best Quote
Rs 1,50,000  / PiecePrice on Request
MaterialStainless Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-282
PositioningTrolley
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%
  • During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Anesthesia Machine Manufacturer

  • Anesthesia Machine Manufacturer
  • Anesthesia Machine Manufacturer
  • Anesthesia Machine Manufacturer
Anesthesia Machine Manufacturer
Get Best Quote
Rs 1,70,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

MaterialStainless Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-282
PositioningTrolley
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%, During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Anesthesia Machine Vaporizer

  • Anesthesia Machine Vaporizer
  • Anesthesia Machine Vaporizer
  • Anesthesia Machine Vaporizer
Anesthesia Machine Vaporizer
Get Best Quote
Rs 1,80,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

MaterialMild Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-282
PositioningTrolley
Country of OriginMade in India
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%, During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Semi Automatic Stainless Steel Boyles Apparatus For Operation Use

  • Semi Automatic Stainless Steel Boyles Apparatus For Operation Use
  • Semi Automatic Stainless Steel Boyles Apparatus For Operation Use
Semi Automatic Stainless Steel Boyles Apparatus For Operation Use
Get Best Quote
Rs 90,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Machine TypeBasic Boyles
No of Gas Lines2 gas
Vaporizer SlotsDouble
Usage/ApplicationICU Use
TypeSimple Boyle's Apparatus
Patient TypeAdult & Paed
Model Name/NumberME-202
PositioningTrolley
Anaesthetic AgentsSevoflurane, Isoflurane, Halothane
MaterialStainless Steel
Country of OriginMade in India
Automation GradeManual

Safety Features:

  • N2O Automatic cut off in case failure of oxygen supply.
  • Low-pressure Oxygen Audible Alarm.
  • Hypoxic-Guard Device-Ensures protection against Singular Flow of N2O until a minimum flow of 1Ltr. oxygen is released.


Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Mild Steel Anesthesia Boyles Apparatus

  • Mild Steel Anesthesia Boyles Apparatus
  • Mild Steel Anesthesia Boyles Apparatus
  • Mild Steel Anesthesia Boyles Apparatus
Mild Steel Anesthesia Boyles Apparatus
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
Automation GradeManual
Model Name/NumberME-15
MaterialMild Steel
BrandME
TypeSimple Boyle's Apparatus
Usage/ApplicationOperation Use
  • Two gases rotameter oxygen & Nitrous-Oxide
  • Standard Fresh Gas Outlet.
  • Change over system open circuit to close a circuit.
  • Emergency Flush Valve.
  • Goldman Type Halothane Vaporizer.
  • Non-return cum Pressure Relief Valve.
  • Blows off valve when the pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon Dioxide Absorber.
  • An extended platform at rear for two ‘B’ type cylinders.
  • One spacious drawer on a smooth runner.
  • Four castor trolley with front two lockable wheels.
  • High-efficiency Regulators for reliability two each for O2 & N2O.


Safety Features:

  • N2O cut off in case failure of Oxygen supply.
  • Low-pressure Oxygen Audible Alarm.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Boyle's Apparatus Minor

  • Boyle's Apparatus Minor
  • Boyle's Apparatus Minor
  • Boyle's Apparatus Minor
Boyle's Apparatus Minor
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
Automation GradeManual
Model Name/NumberME-11
MaterialMild Steel
BrandME
TypeSimple Boyle's Apparatus
Usage/ApplicationOperation Use
PositioningTrolley
Country of OriginMade in India

Specifications-

Two gases rotameter O2 & N2O

Common Gas Out Let.

Goldman Type Halothane Vaporizer.

Non-return cum pressure relief valve to minimize risk of back flow of gases.

Extended platform at rear space for One ‘B’ Type O2 Cylinders

Table top stainless steel.

Top tray provided at eye level for Monitoring equipment.

Bains Circuit.

One spacious Drawer on smooth runner.

Emergency Oxygen push button.

Pin Index yokes One each for Oxygen & Nitrous Oxide.

High Efficiency regulators for reliability One each for O2 & N2O.

Attachment for ‘B’ type .

Four castor trolley with front Two lockable wheels.

Low Pressure oxygen audible alarm.

Optional:

 

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Mild Steel Boyles Apparatus For Operation Use

  • Mild Steel Boyles Apparatus For Operation Use
  • Mild Steel Boyles Apparatus For Operation Use
  • Mild Steel Boyles Apparatus For Operation Use
  • Mild Steel Boyles Apparatus For Operation Use
Mild Steel Boyles Apparatus For Operation Use
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
Machine TypeBasic Boyles
No of Gas Lines2 gas
Vaporizer SlotsSingle
Automation GradeSemi Automatic
Usage/ApplicationOperation Use
TypeSimple Boyle's Apparatus
Model Name/NumberME-15
MaterialMild Steel
Country of OriginMade in India
Details:
  • Two gases rotameter oxygen & Nitrous-Oxide
  • Standard Fresh Gas Outlet.
  • Change over system open circuit to close a circuit.
  • Emergency Flush Valve.
  • Goldman Type Halothane Vaporizer.
  • Non-return cum Pressure Relief Valve.
  • Blows off valve when the pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon Dioxide Absorber.
  • An extended platform at rear for two ‘B’ type cylinders.
  • One spacious drawer on a smooth runner.
  • Four castor trolley with front two lockable wheels.
  • High-efficiency Regulators for reliability two each for O2 & N2O.


Safety Features:

  • N2O cut off in case failure of Oxygen supply.
  • Low-pressure Oxygen Audible Alarm.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Mild Steel MS Portable Anesthesia Machine

  • Mild Steel MS Portable Anesthesia Machine
  • Mild Steel MS Portable Anesthesia Machine
Mild Steel MS Portable Anesthesia Machine
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
Positioning TypeTrolley
Model Name/NumberME-11
MaterialMild Steel
Usage/ApplicationOperation Use
BrandME
Automation GradeManual
PositioningTrolley

Specifications-

Two gases rotameter O2 & N2O

Common Gas Out Let.

Goldman Type Halothane Vaporizer.

Non-return cum pressure relief valve to minimize risk of back flow of gases.

Extended platform at rear space for One ‘B’ Type O2 Cylinders

Table top stainless steel.

Top tray provided at eye level for Monitoring equipment.

Bains Circuit.

One spacious Drawer on smooth runner.

Emergency Oxygen push button.

Pin Index yokes One each for Oxygen & Nitrous Oxide.

High Efficiency regulators for reliability One each for O2 & N2O.

Attachment for ‘B’ type .

Four castor trolley with front Two lockable wheels.

Low Pressure oxygen audible alarm.

Optional:

 

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Anaesthesia Trolley Mild Steel

  • Anaesthesia Trolley Mild Steel
  • Anaesthesia Trolley Mild Steel
  • Anaesthesia Trolley Mild Steel
Anaesthesia Trolley Mild Steel
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
MaterialPowder Coated Steel
ColorWhite
Model Name/NumberME-15
CategoryANESTHESIA TROLLEY
Usage/ApplicationANESTHESIA
Cylinder yokes4
  • Two gases rotameter oxygen & Nitrous-Oxide
  • Standard Fresh Gas Outlet.
  • Change over system open circuit to close a circuit.
  • Emergency Flush Valve.
  • Goldman Type Halothane Vaporizer.
  • Non-return cum Pressure Relief Valve.
  • Blows off valve when the pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon Dioxide Absorber.
  • An extended platform at rear for two ‘B’ type cylinders.
  • One spacious drawer on a smooth runner.
  • Four castor trolley with front two lockable wheels.
  • High-efficiency Regulators for reliability two each for O2 & N2O.


Safety Features:

  • N2O cut off in case failure of Oxygen supply.
  • Low-pressure Oxygen Audible Alarm.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.


Additional Information:

  • Delivery Time: 7 TO 10 DAYS
  • Packaging Details: BOX

View Complete details

Yes! I am Interested Request a call back

Mild Steel ME-15 Anesthesia Machine

  • Mild Steel ME-15 Anesthesia Machine
  • Mild Steel ME-15 Anesthesia Machine
  • Mild Steel ME-15 Anesthesia Machine
  • Mild Steel ME-15 Anesthesia Machine
  • Mild Steel ME-15 Anesthesia Machine
Mild Steel ME-15 Anesthesia Machine
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
MaterialMild Steel
Usage/ApplicationOperation Use
Automation GradeSemi-automatic
Model Name/NumberME-15
BrandME
PositioningTrolley
Details:
  • Two gases rotameter oxygen & Nitrous-Oxide
  • Standard Fresh Gas Outlet.
  • Change over system open circuit to close a circuit.
  • Emergency Flush Valve.
  • Goldman Type Halothane Vaporizer.
  • Non-return cum Pressure Relief Valve.
  • Blows off valve when the pressure exceeds 200cm of water column fitted.
  • Provision to fit ventilator.
  • Provision to fit carbon Dioxide Absorber.
  • An extended platform at rear for two ‘B’ type cylinders.
  • One spacious drawer on a smooth runner.
  • Four castor trolley with front two lockable wheels.
  • High-efficiency Regulators for reliability two each for O2 & N2O.


Safety Features:

  • N2O cut off in case failure of Oxygen supply.
  • Low-pressure Oxygen Audible Alarm.

Optional:
  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Boyels Apparatus Anaesthesia

  • Boyels Apparatus Anaesthesia
  • Boyels Apparatus Anaesthesia
  • Boyels Apparatus Anaesthesia
Boyels Apparatus Anaesthesia
Get Best Quote
Rs 1,50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Size630 x 480 x 930mm
MaterialStainless Steel
Usage/ApplicationANESTHESIA
ColorSilver
Model Name/NumberME-282
Drawers4
Safety Features:
  • N2O automatic cutoff in case failure of oxygen supply.
  • Low-pressure oxygen audible alarm.
  • ORC (Oxygen Ratio Control) Oxygen Concentration remains above 25%
  • During the process, when oxygen supply pressure is deficient, N2O flow gradually decreases till cut-off.

Optional:

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details

Yes! I am Interested Request a call back

Epoxy Coating Anesthesia Machine

  • Epoxy Coating Anesthesia Machine
  • Epoxy Coating Anesthesia Machine
Epoxy Coating Anesthesia Machine
Get Best Quote
Price on Request

Product Brochure

Minimum Order Quantity1 UNIT
Coating MaterialIron
Operation ModeManual
Working PressureMedium
BrandME
ApplicationCoating

Specifications-

Two gases rotameter O2 & N2O

Common Gas Out Let.

Goldman Type Halothane Vaporizer.

Non-return cum pressure relief valve to minimize risk of back flow of gases.

Extended platform at rear space for One ‘B’ Type O2 Cylinders

Table top stainless steel.

Top tray provided at eye level for Monitoring equipment.

Bains Circuit.

One spacious Drawer on smooth runner.

Emergency Oxygen push button.

Pin Index yokes One each for Oxygen & Nitrous Oxide.

High Efficiency regulators for reliability One each for O2 & N2O.

Attachment for ‘B’ type .

Four castor trolley with front Two lockable wheels.

Low Pressure oxygen audible alarm.

Optional:

 

  • Circle Absorber.
  • Anesthesia Ventilator.
  • Vaporizer.
  • Mox Regulator.
  • Monitor.
  • Cylinders.

View Complete details